Endoscopic Removal of an Ingested Mercury Glass Thermometer: A Case Report
Keywords:
Foreign body, thermometer, endoscopy, esophagus
Abstract
Foreign body ingestion is a potentially lethal condition and the wide variety of ingested foreign bodies poses a challenge in the management of these patients. Endoscopic removal is the first-line treatment for ingested foreign bodies that need to be removed either due to their harmful potential or because they will most likely fail to pass per anus. We report the retrieval of an ingested thermometer from the stomach of a young schizophrenic male by endoscopic means.
References
1. Sugawa C, Ono H, Taleb M, Lucas CE. Endoscopic management of foreign bodies in the upper gastrointestinal tract: A review. World J Gastrointest Endosc. 2014; 6:475 81.
2. Emara MH, Darwiesh EM, Refaey MM, Galal SM. Endoscopic removal of foreign bodies from the upper gastrointestinal tract: 5 year experience. Clin Exp Gastroenterol
2014; 7:249 53.
3. Birk M, Bauerfeind P, Deprez PH, Häfner M, Hartmann D, Hassan C, et al. Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of
Gastrointestinal Endoscopy (ESGE) clinical guideline. Endoscopy 2016; 48:489 96.
4. Hong KH, Kim YJ, Kim JH, Chun SW, Kim HM, Cho JH. Risk factors for complications associated with upper gastrointestinal foreign bodies. World J Gastroenterol 2015; 21:8125 31.
5. Jonas SK. Fiberendoscopic removal of ingested thermometer. A case report. Del Med J, 1984; 56: 357-8
6. Kerlin P, Paull A. Removal of duodenal foreign body with endoscopic snare. Med J Aust, 1978; 2: 276-7
7. Dokas S, Koliouskas D, Masmanidou M, Ziakas G. Endoscopic removal of an ingested thermometer. Case Rep Clin Pract Rev. 2003; 4(3): 193-195
8. Feldman M, Friedman LS, Brandt LJ, Chung RT, Rubin DT. Wilcox CM. Sleisenger and Fordtran’s Gastrointestinal and Liver Disease. 11th edition. Philadelphia, PA: Elsevier, 2021.
9. Bredfeld JE, Moeller DD. Systemic mercury intoxication following rupture of a Miller-Abbott tube. Am J Gastroenterol. 1978; 69: 478-80
10. Naciancero, S.E. and Joseph, R.R. Therapeutic Endoscopy: removal of an unusual foreign object from stomach. Gastrointest. Endoscopy.1974; 21: 34.
2. Emara MH, Darwiesh EM, Refaey MM, Galal SM. Endoscopic removal of foreign bodies from the upper gastrointestinal tract: 5 year experience. Clin Exp Gastroenterol
2014; 7:249 53.
3. Birk M, Bauerfeind P, Deprez PH, Häfner M, Hartmann D, Hassan C, et al. Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of
Gastrointestinal Endoscopy (ESGE) clinical guideline. Endoscopy 2016; 48:489 96.
4. Hong KH, Kim YJ, Kim JH, Chun SW, Kim HM, Cho JH. Risk factors for complications associated with upper gastrointestinal foreign bodies. World J Gastroenterol 2015; 21:8125 31.
5. Jonas SK. Fiberendoscopic removal of ingested thermometer. A case report. Del Med J, 1984; 56: 357-8
6. Kerlin P, Paull A. Removal of duodenal foreign body with endoscopic snare. Med J Aust, 1978; 2: 276-7
7. Dokas S, Koliouskas D, Masmanidou M, Ziakas G. Endoscopic removal of an ingested thermometer. Case Rep Clin Pract Rev. 2003; 4(3): 193-195
8. Feldman M, Friedman LS, Brandt LJ, Chung RT, Rubin DT. Wilcox CM. Sleisenger and Fordtran’s Gastrointestinal and Liver Disease. 11th edition. Philadelphia, PA: Elsevier, 2021.
9. Bredfeld JE, Moeller DD. Systemic mercury intoxication following rupture of a Miller-Abbott tube. Am J Gastroenterol. 1978; 69: 478-80
10. Naciancero, S.E. and Joseph, R.R. Therapeutic Endoscopy: removal of an unusual foreign object from stomach. Gastrointest. Endoscopy.1974; 21: 34.
Published
2021-06-29
How to Cite
Dr. Vishal Bodh, Dr. Rajesh Sharma, Dr. Brij Sharma, Dr. Rajesh Kumar. (2021). Endoscopic Removal of an Ingested Mercury Glass Thermometer: A Case Report. The Indian Practitioner, 74(6), 54-66. Retrieved from https://articles.theindianpractitioner.com/index.php/tip/article/view/1197
Section
Case Reports